1 March 2021

Barco Projector Repair

Barco Projector Repairs

Barco Repair Service

[vc_cta h2=””]

Barco error code 5647, error code 6200, error code 7980, Barco Low Frequency Maintenance Error, Barco fan failure; voltage on fan group too high, fan is running too slow or not at all. Barco lamp replacement, hot restrike,lamp with many strikes, maximum run time exceeded, Temperature sensor on Red DMD shorted,  initialization of the scaler failed error and many more.

[/vc_cta]

[vc_cta h2=”We also stock Barco UPH lamps, FLM lamps, Xenon lamps and many more.”][/vc_cta]

Barco Projector Repair with Warranty

Our Barco projector repair services covers the models below and future releases. We also carry out maintenance service for all Barco models.

Freya 4K RGB Laser, SP2K-9 8000 Lumens 2K Laser Phosphor, SP2K-7 6000 Lumens 2K Laser Phosphor, SP2K-15 14000 Lumens 2K Laser Phosphor, SP2K-11 11000 Lumens 2K Laser Phosphor, SP4K-50 48000 lumens 4K RGB Laser, SP4K-40 40000 Lumens 4K RGB Laser, SP4K-35 35000 Lumens 4K RGB Laser, SP4K-27HC 27000 lumens 4K RGB Laser, FS70-4K4 4000 Lumens 4K Laser Phosphor, F70-4K4 4000 Lumens 4K Laser Posphor, SP4K-25, 23500 Lumens 4K RGB Laser, SP4K-20     20000 Lumens 4K RGB Laser, SP4K-15 17000 Lumens 4K RGB Laser, SP4K-12 12000 Lumens 4K RGB Laser, XDL-4K30     30000 Lumens 4K RGB Laser, XDL-4K60 60000 Lumens 4K RGB Laser, F80-4K7 7000 Lumens 4K Laser Phosphor, F80-4K9,9000 Lumens 4K Laser Phosphor, DP4K-36BLP 35000 Lumens 4K Laser Phosphor, DP4K-40LHC 38000 Lumens 4K RGB Laser, FS70-W6 5500 Lumens WUXGA Laser Phosphor, FS70-4K6 5000 Lumens 4K Laser Phosphor, FS40-WU MKII 3000 Lumens 4K LED FS40-WU 2300 Lumens 4K LED,  FS40-4K MKII 2700 Lumens 4K LED,  FS40-4K 2100 Lumens 4K LED,  FL40-WU MKII 3000 Lumens 4K LED,  FL40-WU 2300 Lumens 4K LED,  FL40-4K MKII 2700 Lumens 4K LE,  FL40-4K 2100 Lumens 4K LED, F70-W6 5500 Lumens WUXGA Laser Phosphor, F70-4K6 5000 Lumens 4K Laser Phosphor,  F90-4K13 11800 Lumens 4K Laser Phosphor, DP2K-20CLP 20000 Lumens 2K Laser Phosphor, DP2K-6E 7200 Lumens 2KLamp, DP4K-60L 56000 Lumens 4K RGB Laser,  DP2K-10S 9000 Lumens 2K Lamp,  DP4K-P 2700 Lumens 4K Lamp, DP4K-32B 33000 Lumens 4K Lamp,  DP2K-20C 18500 Lumens 2K Lamp Balder 7000 Lumens 4K UHD Laser Phosphor, Balder Cinemascope 5600 Lumens Cinemascope (5,120 x 2,160)Laser Phosphor, Barco-Projector-Management-Suite IoT platform to monitor, diagnose and control your projectors Bragi 4K UHD LED 3D, Bragi Cinemascope 2100 Lumens Cinemascope (5,120 x 2,160) LED,  DP2K-10SLP 9000 Lumens 2K Laser Phosphor, DP2K-15C 14500 Lumens 2K Lamp DP2K-15CLP 15000 Lumens 2K Laser Phosphor, DP2K-17BLP 17000 Lumens 2K Laser Phosphor, DP2K-19B 19000 Lumens 2K Lamp DP2K-23B 24500 Lumens 2K Lamp DP2K-23BLP 24000 Lumens 2K Laser Phosphor, DP2K-32B 33000 Lumens 2K Lamp DP2K-36BLP 35000 Lumens 2K Laser Phosphor, DP2K-8S 6000 Lumens 2K Lamp DP2K-8SLP 7000 Lumens 2K Laser Phosphor, DP4K-13BLPHC 11500 Lumens 4K Laser Phosphor, DP4K-17BLP 17000 Lumens 4K Laser Phosphor, DP4K-18BLPHC 16000 Lumens 4K Laser Phosphor, DP4K-19B 19000 Lumens 4K Lamp DP4K-23B 24500 Lumens 4K Lamp DP4K-23BLP 24000 Lumens 4K Laser Phosphor, F50 1080 5000 Lumens HD Lamp,  F50 WQXGA 5000 Lumens WQXGA Lamp, 50 WUXGA 5500 Lumens WUXGA Lamp F70-4K8 7500 Lumens 4K Laser Phosphor, F70-W8 8000 Lumens WUXGA Laser Phosphor, F80-4K12 12000 Lumens 4K Laser Phosphor, F80-Q12 12000 Lumens WQXGA Laser Phosphor, F80-Q7 7000 Lumens WQXGA Laser Phosphor, F80-Q9 9000 Lumens WQXGA Laser Phosphor, F90-W13 13000 Lumens WUXGA Laser Phosphor, G100-W16 16000 Lumens WUXGA Laser Phosphor, G100-W19 19000 Lumens WUXGA Laser Phosphor, G100-W22 22000 Lumens WUXGA Laser Phosphor, G60-W10 10000 Lumens WUXGA Laser Phosphor, G60-W7 7000 Lumens WUXGA Laser Phosphor, G60-W8 8000 Lumens WUXGA Laser Phosphor, Loki 12000 Lumens 4K UHD Laser Phosphor, Loki Cinemascope 7800 Lumens Cinemascope (5,120 x 2,160) Laser Phosphor, MCM-100s External warping, blending and color matching Medea 6500 Lumens 4K UHD Laser Phosphor, Njord 4K UHD 3D Warping Orion Cinemascope 2000 Lumens Cinemascope (2,560 x 1,080) Lamp Prometheus I 6500 Lumens 4K Lamp Prometheus III 11500 Lumens 4K DCI Compliant Thor 15000 Lumens 4K RGB Laser Thor+ 32000 Lumens 4K RGB Laser UDM-4K15 14500 Lumens 4K Laser Phosphor, UDM-4K22 21000 Lumens 4K Laser Phosphor, UDM-W15 14500 Lumens WUXGA Laser Phosphor, UDM-W19 18500 Lumens WUXGA Laser Phosphor, UDM-W22 21000 Lumens WUXGA Laser Phosphor, UDX-4K26 25000 Lumens 4K Laser Phosphor, UDX-4K32 31000 Lumens 4K Laser Phosphor, UDX-4K40 37500 Lumens 4K Laser Phosphor, UDX-U32 30000 Lumens UXGA Laser Phosphor, UDX-U40 39000 Lumens UXGA Laser Phosphor, UDX-U45LC 41000 Lumens UXGA Laser Phosphor, UDX-W26 26000 Lumens WUXGA Laser Phosphor, UDX-W32 32000 Lumens WUXGA Laser Phosphor, UDX-W40 40000 Lumens WUXGA Laser Phosphor, XDL-4K75 75000 Lumens 4K RGB Laser Zeus 8000 Lumens 2K Lamp

[vc_accordion active_tab=”1″ collapsible=”yes”][vc_accordion_tab title=”BARCO PROJECTORS ERROR CODES”][vc_cta h2=”BARCO PROJECTORS ERROR CODES” txt_align=”justify”]

1000-1017Wrong lamp/ no communication with lampCheck lamp type Check lamp type Call a qualified service engineer
1697no communication with formatter ctrlCall a qualified service engineer
1696no communication with formatterCall a qualified service engineer
1695no communication with red formatterCall a qualified service engineer
1694no communication with green formatterCall a qualified service engineer
1693no communication with blue formatterCall a qualified service engineer
1692formatter ‘Power Good’ signal not OKCall a qualified service engineer
2000no communication with lamp powersupplyCall a qualified service engineer
2001mains voltage too lowCall a qualified service engineer
2002Hot restrike Lamp with many strikes maximum run time exceeded Lamp or LPS or SPG failedLet cool down the lamp for at least 5 minutes Retry a few times Replace the lampwith a new one Replace LPS  or SPG or cabling
2003mains voltage too highCall a qualified service engineer
2004Lamp goes outCall a qualified service engineer
2005Lamp stop failedCall a qualified service engineer
2201PFC start failedReplace LPS
2501PFC start failedReplace LPS
2801PFC start failedReplace LPS
2202LFC start failedReplace LPS
2502LFC start failedReplace LPS
2802LPS (address 0x28)Replace LPS
2203LPS (address 0x20)Replace LPS
2503LPS (address 0x22)Replace LPS
2803LPS (address 0x28)Replace LPS
2206hot restrike,lamp with many strikes, maximum run time exceededLet cool down the lamp for at least 3 minutes. Replace the lamp or SPG with a new one If problem persists, call a qualified service engineer
2506hot restrike,lamp with many strikes, maximum run time exceededLet cool down the lamp for at least 3 minutes. Replace the lamp or SPG with a new one If problem persists, call a qualified service engineer
2806hot restrike,lamp with many strikes, maximum run time exceededLet cool down the lamp for at least 3 minutes. Replace the lamp or SPG with a new one If problem persists, call a qualified service engineer
2207lamp voltage too high or too lowReplace lamp
2507lamp voltage too high or too lowReplace lamp
2807lamp voltage too high or too lowReplace lamp
2208lamp voltage too high or too lowReplace lamp
2508lamp voltage too high or too lowReplace lamp
2808lamp voltage too high or too lowReplace lamp
4000Incompatible hardware usedChange to correct hardware
4199no communication with FIBCall a qualified service engineer
5098Internal Backup device has reached its maximum capacityCall a qualified service engineer
5097Internal Backup device has reached its maximum capacityCall a qualified service engineer
5096Storing the custom settings into internal backup device has failedIf problem persists, call a qualified service engineer
5095Restoring the custom settings from internal backup device has failedIf problem persists, call a qualified service engineer
7698High temperature on light pipe entryIf problem persists, call a qualified service engineer
7697Temperature sensor on light pipe not connectedCall a qualified service engineer
7696Temperature sensor on light pipe shortedCall a qualified service engineer
7695Low temperature on red DMDSwitching on the lamp will heat up the DMD
7694High temperature on red DMDCheck if air slots are free.Clean air filters.If problem persists, call a qualified service engineer
7693Temperature sensor on Red DMD not connectedCall a qualified service engineer
7692Temperature sensor on Red DMD shortedCall a qualified service engineer
7691Low temperature on green DMDSwitching on the lamp will heat upthe DMD
7690High temperature on green DMD not connectedCheck if air slots are free.Clean air filters.If problem persists, call a qualified service engineer
7689Temperature sensor on green DMDCall a qualified service engineer
7688Temperature sensor on green DMD shortedCall a qualified service engineer
7687Low temperature on blue DMDSwitching on the lamp will heat upthe DMD
7686High temperature on blue DMDCheck if air slots are free.Clean air filters.If problem persists, call a qualified service engineer
7685Temperature sensor on blue DMD not connectedCall a qualified service engineer
7684Temperature sensor on blue DMD shortedCall a qualified service engineer
7676High temperature on front DMD cooling blockCheck if air slots are free.Clean air filters.If problem persists, call a qualified service engineer
7675Temperature sensor on front cooling block not connectedCall a qualified service engineer
7674Temperature sensor on front cooling block shortedCall a qualified service engineer
7672High temperature on red DMD cooling blockCheck if air slots are free.Clean air filters.If problem persists, call a qualified service engineer
7671Temperature sensor on red DMD cooling block not connectedCall a qualified service engineer
7670Temperature sensor on red DMD cooling block shortedCall a qualified service engineer
7668High temperature on green DMD cooling blockCheck if air slots are free.Clean air filters.If problem persists, call a qualified service engineer
7667Temperature sensor on green DMD cooling block not connectedCall a qualified service engineer
7666Temperature sensor on green DMD cooling block shortedCall a qualified service engineer
7664High temperature on blue DMD cooling blockCheck if air slots are free.Clean air filters.If problem persists, call a qualified service engineer
7663Temperature sensor on blue DMD cooling block not connectedCall a qualified service engineer
7662Temperature sensor on blue DMD cooling block shortedCall a qualified service engineer
7660High temperature on engineCheck if air slots are free.Clean air filters.If problem persists, call a qualified service engineer
7659Temperature sensor on engine notconnectedCall a qualified service engineer
7658Temperature sensor on engineshortedCall a qualified service engineer
7999fan is running too slow or not at allIf problem persists, call a qualified service engineer
7997fan is running too slow or not at allIf problem persists, call a qualified service engineer
7995fan is running too slow or not at allIf problem persists, call a qualified service engineer
7993fan is running too slow or not at allIf problem persists, call a qualified service engineer
7991fan is running too slow or not at allIf problem persists, call a qualified service engineer
7989fan is running too slow or not at allIf problem persists, call a qualified service engineer
7987fan is running too slow or not at allIf problem persists, call a qualified service engineer
7985low temperature on dmdturning on the lamp will heat up the dmd
7984high temperature on dmdcheck if air slot are free; clean airfilters If problem persists, call a qualified service engineer
7983low temperature on dmdturning on the lamp will heat up the dmd
7982high temperature on dmdcheck if air slot are free; clean airfilters If problem persists, call a qualified service engineer
7981low temperature on dmdturning on the lamp will heat up thedmd
7980high temperature on dmdcheck if air slot are free; clean airfiltersIf problem persists, call a qualified service engineer
7978high temperature lampcheck if air slot are free; clean airfilters If problem persists, call a qualified service engineer
7976high temperature on smpscheck if air slot are free; clean airfilters If problem persists, call a qualified service engineer
7974ambient temperature abovespecificationcheck ambient conditionscheck if air slot are free; clean airfilters
7973ambient temperature abovespecificationHardware problem in Fan controlboard, call a qualified serviceengineer
7972voltage on fan group 1 too highHardware problem in Fan controlboard, call a qualified serviceengineer
7971voltage on fan group 2 too low (=anode fan)Hardware problem in Fan controlboard, call a qualified serviceengineer
7970voltage on fan group 2 too highHardware problem in Fan controlboard, call a qualified serviceengineer
7969voltage on fan group 3 too low (=engine fan)Hardware problem in Fan controlboard, call a qualified serviceengineer
7968voltage on fan group 3 too highHardware problem in Fan controlboard, call a qualified serviceengineer
7967voltage on fan group 4 too low (=cold mirror + head ex. fan)Hardware problem in Fan controlboard, call a qualified serviceengineer
7966voltage on fan group 4 too high (=cold mirror + head ex. fan)Hardware problem in Fan controlboard, call a qualified serviceengineer
7965voltage on fan group 5 too low (=mains input fan)Hardware problem in Fan controlboard, call a qualified serviceengineer
7964voltage on fan group 5 too highmains input fan)Hardware problem in Fan controlboard, call a qualified serviceengineer
7963voltage on fan group 6 too low (=smps fan)Hardware problem in Fan controlboard, call a qualified serviceengineer
7962voltage on fan group 6 too low (=smps fan)Hardware problem in Fan controlboard, call a qualified serviceengineer
7959voltage on pump too lowIf problem persists, call a qualified service engineer
7958voltage on pump too highIf problem persists, call a qualified service engineer
7957supply voltage for fans too lowIf problem persists, call a qualified service engineer
7956supply voltage for fans too highIf problem persists, call a qualified service engineer
7955supply voltage for DMD cooling toolowIf problem persists, call a qualified service engineer
7954supply voltage for DMD cooling toohighIf problem persists, call a qualifiedservice engineer
7953supply voltage for motors too lowIf problem persists, call a qualifiedservice engineer
7952supply voltage for motors too highIf problem persists, call a qualifiedservice engineer
7945supply voltage for electronics toolowIf problem persists, call a qualifiedservice engineer
7944supply voltage for electronics toohighIf problem persists, call a qualifiedservice engineer
7943supply voltage for engineelectronics too lowIf problem persists, call a qualifiedservice engineer
7942supply voltage for engineelectronics too highIf problem persists, call a qualifiedservice engineer
7941supply voltage for drawerelectronics too lowIf problem persists, call a qualifiedservice engineer
7940supply voltage for drawerelectronics too highIf problem persists, call a qualifiedservice engineer
7939projection lens to close to prismmove lens away from prism (upand/or right)
7938lamp module not correctly insertedreinsert lamp module and screw firmly
7937bad or no water flow in cooling circuitIf problem persists, call a qualified service engineer
7936tilt angle is out of specificationsCorrect projection installation.Change the tilting so that thetilt angle becomes within thespecifications
7935engine is not correctly insertedIf problem persists, call a qualifie dservice engineer
7934formatter interface board is not correctly insertedIf problem persists, call a qualified service engineer
7931high temperature on smpscheck if air slot are free; clean airfilters If problem persists, call aqualified service engineer
7929high temperature on smpscheck if air slot are free; clean airfilters If problem persists, call aqualified service engineer
7928extreme overheating of dmd’s or lampIf problem persists, call a qualified service engineer
7927fan is not running or is running tooslowIf problem persists, call a qualified service engineer
8000If problem persists, call a qualified service engineer
8001If problem persists, call a qualified service engineer
8002If problem persists, call a qualified service engineer
9000Initialization of the scaler failedIf problem persists, call a qualified service engineer
9198BW or refresh rate of input sourcetoo highIf problem persists, call a qualified service engineer
9398Reaching the maximum allowednumber of filesDelete some unnecessary files
10498Module with obsolete firmwareCall a qualified service engineer

[/vc_cta][/vc_accordion_tab][/vc_accordion]