Barco Projector Repair

Barco error code 5647, error code 6200, error code 7980, Barco Low Frequency Maintenance Error, Barco fan failure; voltage on fan group too high, fan is running too slow or not at all. Barco lamp replacement, hot restrike,lamp with many strikes, maximum run time exceeded, Temperature sensor on Red DMD shorted,  initialization of the scaler failed error and many more.

Our Barco projector repair services covers the models below and future releases. We also carry out maintenance service for all Barco models.

Freya 4K RGB Laser, SP2K-9 8000 Lumens 2K Laser Phosphor, SP2K-7 6000 Lumens 2K Laser Phosphor, SP2K-15 14000 Lumens 2K Laser Phosphor, SP2K-11 11000 Lumens 2K Laser Phosphor, SP4K-50 48000 lumens 4K RGB Laser, SP4K-40 40000 Lumens 4K RGB Laser, SP4K-35 35000 Lumens 4K RGB Laser, SP4K-27HC 27000 lumens 4K RGB Laser, FS70-4K4 4000 Lumens 4K Laser Phosphor, F70-4K4 4000 Lumens 4K Laser Posphor, SP4K-25, 23500 Lumens 4K RGB Laser, SP4K-20 20000 Lumens 4K RGB Laser, SP4K-15 17000 Lumens 4K RGB Laser, SP4K-12 12000 Lumens 4K RGB Laser, XDL-4K30 30000 Lumens 4K RGB Laser, XDL-4K60 60000 Lumens 4K RGB Laser, F80-4K7 7000 Lumens 4K Laser Phosphor, F80-4K9,9000 Lumens 4K Laser Phosphor, DP4K-36BLP 35000 Lumens 4K Laser Phosphor, DP4K-40LHC 38000 Lumens 4K RGB Laser, FS70-W6 5500 Lumens WUXGA Laser Phosphor, FS70-4K6 5000 Lumens 4K Laser Phosphor, FS40-WU MKII 3000 Lumens 4K LED FS40-WU 2300 Lumens 4K LED, FS40-4K MKII 2700 Lumens 4K LED, FS40-4K 2100 Lumens 4K LED, FL40-WU MKII 3000 Lumens 4K LED, FL40-WU 2300 Lumens 4K LED, FL40-4K MKII 2700 Lumens 4K LE, FL40-4K 2100 Lumens 4K LED, F70-W6 5500 Lumens WUXGA Laser Phosphor, F70-4K6 5000 Lumens 4K Laser Phosphor, F90-4K13 11800 Lumens 4K Laser Phosphor, DP2K-20CLP 20000 Lumens 2K Laser Phosphor, DP2K-6E 7200 Lumens 2KLamp, DP4K-60L 56000 Lumens 4K RGB Laser, DP2K-10S 9000 Lumens 2K Lamp, DP4K-P 2700 Lumens 4K Lamp, DP4K-32B 33000 Lumens 4K Lamp, DP2K-20C 18500 Lumens 2K Lamp Balder 7000 Lumens 4K UHD Laser Phosphor, Balder Cinemascope 5600 Lumens Cinemascope (5,120 x 2,160)Laser Phosphor, Barco-Projector-Management-Suite IoT platform to monitor, diagnose and control your projectors Bragi 4K UHD LED 3D, Bragi Cinemascope 2100 Lumens Cinemascope (5,120 x 2,160) LED, DP2K-10SLP 9000 Lumens 2K Laser Phosphor, DP2K-15C 14500 Lumens 2K Lamp DP2K-15CLP 15000 Lumens 2K Laser Phosphor, DP2K-17BLP 17000 Lumens 2K Laser Phosphor, DP2K-19B 19000 Lumens 2K Lamp DP2K-23B 24500 Lumens 2K Lamp DP2K-23BLP 24000 Lumens 2K Laser Phosphor, DP2K-32B 33000 Lumens 2K Lamp DP2K-36BLP 35000 Lumens 2K Laser Phosphor, DP2K-8S 6000 Lumens 2K Lamp DP2K-8SLP 7000 Lumens 2K Laser Phosphor, DP4K-13BLPHC 11500 Lumens 4K Laser Phosphor, DP4K-17BLP 17000 Lumens 4K Laser Phosphor, DP4K-18BLPHC 16000 Lumens 4K Laser Phosphor, DP4K-19B 19000 Lumens 4K Lamp DP4K-23B 24500 Lumens 4K Lamp DP4K-23BLP 24000 Lumens 4K Laser Phosphor, F50 1080 5000 Lumens HD Lamp, F50 WQXGA 5000 Lumens WQXGA Lamp, 50 WUXGA 5500 Lumens WUXGA Lamp F70-4K8 7500 Lumens 4K Laser Phosphor, F70-W8 8000 Lumens WUXGA Laser Phosphor, F80-4K12 12000 Lumens 4K Laser Phosphor, F80-Q12 12000 Lumens WQXGA Laser Phosphor, F80-Q7 7000 Lumens WQXGA Laser Phosphor, F80-Q9 9000 Lumens WQXGA Laser Phosphor, F90-W13 13000 Lumens WUXGA Laser Phosphor, G100-W16 16000 Lumens WUXGA Laser Phosphor, G100-W19 19000 Lumens WUXGA Laser Phosphor, G100-W22 22000 Lumens WUXGA Laser Phosphor, G60-W10 10000 Lumens WUXGA Laser Phosphor, G60-W7 7000 Lumens WUXGA Laser Phosphor, G60-W8 8000 Lumens WUXGA Laser Phosphor, Loki 12000 Lumens 4K UHD Laser Phosphor, Loki Cinemascope 7800 Lumens Cinemascope (5,120 x 2,160) Laser Phosphor, MCM-100s External warping, blending and color matching Medea 6500 Lumens 4K UHD Laser Phosphor, Njord 4K UHD 3D Warping Orion Cinemascope 2000 Lumens Cinemascope (2,560 x 1,080) Lamp Prometheus I 6500 Lumens 4K Lamp Prometheus III 11500 Lumens 4K DCI Compliant Thor 15000 Lumens 4K RGB Laser Thor+ 32000 Lumens 4K RGB Laser UDM-4K15 14500 Lumens 4K Laser Phosphor, UDM-4K22 21000 Lumens 4K Laser Phosphor, UDM-W15 14500 Lumens WUXGA Laser Phosphor, UDM-W19 18500 Lumens WUXGA Laser Phosphor, UDM-W22 21000 Lumens WUXGA Laser Phosphor, UDX-4K26 25000 Lumens 4K Laser Phosphor, UDX-4K32 31000 Lumens 4K Laser Phosphor, UDX-4K40 37500 Lumens 4K Laser Phosphor, UDX-U32 30000 Lumens UXGA Laser Phosphor, UDX-U40 39000 Lumens UXGA Laser Phosphor, UDX-U45LC 41000 Lumens UXGA Laser Phosphor, UDX-W26 26000 Lumens WUXGA Laser Phosphor, UDX-W32 32000 Lumens WUXGA Laser Phosphor, UDX-W40 40000 Lumens WUXGA Laser Phosphor, XDL-4K75 75000 Lumens 4K RGB Laser Zeus 8000 Lumens 2K Lamp

BARCO PROJECTORS ERROR CODES

1000-1017 Wrong lamp/ no communication with lamp Check lamp type Check lamp type Call a qualified service engineer
1697 no communication with formatter ctrl Call a qualified service engineer
1696 no communication with formatter Call a qualified service engineer
1695 no communication with red formatter Call a qualified service engineer
1694 no communication with green formatter Call a qualified service engineer
1693 no communication with blue formatter Call a qualified service engineer
1692 formatter ‘Power Good’ signal not OK Call a qualified service engineer
2000 no communication with lamp powersupply Call a qualified service engineer
2001 mains voltage too low Call a qualified service engineer
2002 Hot restrike Lamp with many strikes maximum run time exceeded Lamp or LPS or SPG failed Let cool down the lamp for at least 5 minutes Retry a few times Replace the lampwith a new one Replace LPS  or SPG or cabling
2003 mains voltage too high Call a qualified service engineer
2004 Lamp goes out Call a qualified service engineer
2005 Lamp stop failed Call a qualified service engineer
2201 PFC start failed Replace LPS
2501 PFC start failed Replace LPS
2801 PFC start failed Replace LPS
2202 LFC start failed Replace LPS
2502 LFC start failed Replace LPS
2802 LPS (address 0x28) Replace LPS
2203 LPS (address 0x20) Replace LPS
2503 LPS (address 0x22) Replace LPS
2803 LPS (address 0x28) Replace LPS
2206 hot restrike,lamp with many strikes, maximum run time exceeded Let cool down the lamp for at least 3 minutes. Replace the lamp or SPG with a new one If problem persists, call a qualified service engineer
2506 hot restrike,lamp with many strikes, maximum run time exceeded Let cool down the lamp for at least 3 minutes. Replace the lamp or SPG with a new one If problem persists, call a qualified service engineer
2806 hot restrike,lamp with many strikes, maximum run time exceeded Let cool down the lamp for at least 3 minutes. Replace the lamp or SPG with a new one If problem persists, call a qualified service engineer
2207 lamp voltage too high or too low Replace lamp
2507 lamp voltage too high or too low Replace lamp
2807 lamp voltage too high or too low Replace lamp
2208 lamp voltage too high or too low Replace lamp
2508 lamp voltage too high or too low Replace lamp
2808 lamp voltage too high or too low Replace lamp
4000 Incompatible hardware used Change to correct hardware
4199 no communication with FIB Call a qualified service engineer
5098 Internal Backup device has reached its maximum capacity Call a qualified service engineer
5097 Internal Backup device has reached its maximum capacity Call a qualified service engineer
5096 Storing the custom settings into internal backup device has failed If problem persists, call a qualified service engineer
5095 Restoring the custom settings from internal backup device has failed If problem persists, call a qualified service engineer
7698 High temperature on light pipe entry If problem persists, call a qualified service engineer
7697 Temperature sensor on light pipe not connected Call a qualified service engineer
7696 Temperature sensor on light pipe shorted Call a qualified service engineer
7695 Low temperature on red DMD Switching on the lamp will heat up the DMD
7694 High temperature on red DMD Check if air slots are free.Clean air filters.If problem persists, call a qualified service engineer
7693 Temperature sensor on Red DMD not connected Call a qualified service engineer
7692 Temperature sensor on Red DMD shorted Call a qualified service engineer
7691 Low temperature on green DMD Switching on the lamp will heat upthe DMD
7690 High temperature on green DMD not connected Check if air slots are free.Clean air filters.If problem persists, call a qualified service engineer
7689 Temperature sensor on green DMD Call a qualified service engineer
7688 Temperature sensor on green DMD shorted Call a qualified service engineer
7687 Low temperature on blue DMD Switching on the lamp will heat upthe DMD
7686 High temperature on blue DMD Check if air slots are free.Clean air filters.If problem persists, call a qualified service engineer
7685 Temperature sensor on blue DMD not connected Call a qualified service engineer
7684 Temperature sensor on blue DMD shorted Call a qualified service engineer
7676 High temperature on front DMD cooling block Check if air slots are free.Clean air filters.If problem persists, call a qualified service engineer
7675 Temperature sensor on front cooling block not connected Call a qualified service engineer
7674 Temperature sensor on front cooling block shorted Call a qualified service engineer
7672 High temperature on red DMD cooling block Check if air slots are free.Clean air filters.If problem persists, call a qualified service engineer
7671 Temperature sensor on red DMD cooling block not connected Call a qualified service engineer
7670 Temperature sensor on red DMD cooling block shorted Call a qualified service engineer
7668 High temperature on green DMD cooling block Check if air slots are free.Clean air filters.If problem persists, call a qualified service engineer
7667 Temperature sensor on green DMD cooling block not connected Call a qualified service engineer
7666 Temperature sensor on green DMD cooling block shorted Call a qualified service engineer
7664 High temperature on blue DMD cooling block Check if air slots are free.Clean air filters.If problem persists, call a qualified service engineer
7663 Temperature sensor on blue DMD cooling block not connected Call a qualified service engineer
7662 Temperature sensor on blue DMD cooling block shorted Call a qualified service engineer
7660 High temperature on engine Check if air slots are free.Clean air filters.If problem persists, call a qualified service engineer
7659 Temperature sensor on engine notconnected Call a qualified service engineer
7658 Temperature sensor on engineshorted Call a qualified service engineer
7999 fan is running too slow or not at all If problem persists, call a qualified service engineer
7997 fan is running too slow or not at all If problem persists, call a qualified service engineer
7995 fan is running too slow or not at all If problem persists, call a qualified service engineer
7993 fan is running too slow or not at all If problem persists, call a qualified service engineer
7991 fan is running too slow or not at all If problem persists, call a qualified service engineer
7989 fan is running too slow or not at all If problem persists, call a qualified service engineer
7987 fan is running too slow or not at all If problem persists, call a qualified service engineer
7985 low temperature on dmd turning on the lamp will heat up the dmd
7984 high temperature on dmd check if air slot are free; clean airfilters If problem persists, call a qualified service engineer
7983 low temperature on dmd turning on the lamp will heat up the dmd
7982 high temperature on dmd check if air slot are free; clean airfilters If problem persists, call a qualified service engineer
7981 low temperature on dmd turning on the lamp will heat up thedmd
7980 high temperature on dmd check if air slot are free; clean airfiltersIf problem persists, call a qualified service engineer
7978 high temperature lamp check if air slot are free; clean airfilters If problem persists, call a qualified service engineer
7976 high temperature on smps check if air slot are free; clean airfilters If problem persists, call a qualified service engineer
7974 ambient temperature abovespecification check ambient conditionscheck if air slot are free; clean airfilters
7973 ambient temperature abovespecification Hardware problem in Fan controlboard, call a qualified serviceengineer
7972 voltage on fan group 1 too high Hardware problem in Fan controlboard, call a qualified serviceengineer
7971 voltage on fan group 2 too low (=anode fan) Hardware problem in Fan controlboard, call a qualified serviceengineer
7970 voltage on fan group 2 too high Hardware problem in Fan controlboard, call a qualified serviceengineer
7969 voltage on fan group 3 too low (=engine fan) Hardware problem in Fan controlboard, call a qualified serviceengineer
7968 voltage on fan group 3 too high Hardware problem in Fan controlboard, call a qualified serviceengineer
7967 voltage on fan group 4 too low (=cold mirror + head ex. fan) Hardware problem in Fan controlboard, call a qualified serviceengineer
7966 voltage on fan group 4 too high (=cold mirror + head ex. fan) Hardware problem in Fan controlboard, call a qualified serviceengineer
7965 voltage on fan group 5 too low (=mains input fan) Hardware problem in Fan controlboard, call a qualified serviceengineer
7964 voltage on fan group 5 too highmains input fan) Hardware problem in Fan controlboard, call a qualified serviceengineer
7963 voltage on fan group 6 too low (=smps fan) Hardware problem in Fan controlboard, call a qualified serviceengineer
7962 voltage on fan group 6 too low (=smps fan) Hardware problem in Fan controlboard, call a qualified serviceengineer
7959 voltage on pump too low If problem persists, call a qualified service engineer
7958 voltage on pump too high If problem persists, call a qualified service engineer
7957 supply voltage for fans too low If problem persists, call a qualified service engineer
7956 supply voltage for fans too high If problem persists, call a qualified service engineer
7955 supply voltage for DMD cooling toolow If problem persists, call a qualified service engineer
7954 supply voltage for DMD cooling toohigh If problem persists, call a qualifiedservice engineer
7953 supply voltage for motors too low If problem persists, call a qualifiedservice engineer
7952 supply voltage for motors too high If problem persists, call a qualifiedservice engineer
7945 supply voltage for electronics toolow If problem persists, call a qualifiedservice engineer
7944 supply voltage for electronics toohigh If problem persists, call a qualifiedservice engineer
7943 supply voltage for engineelectronics too low If problem persists, call a qualifiedservice engineer
7942 supply voltage for engineelectronics too high If problem persists, call a qualifiedservice engineer
7941 supply voltage for drawerelectronics too low If problem persists, call a qualifiedservice engineer
7940 supply voltage for drawerelectronics too high If problem persists, call a qualifiedservice engineer
7939 projection lens to close to prism move lens away from prism (upand/or right)
7938 lamp module not correctly inserted reinsert lamp module and screw firmly
7937 bad or no water flow in cooling circuit If problem persists, call a qualified service engineer
7936 tilt angle is out of specifications Correct projection installation.Change the tilting so that thetilt angle becomes within thespecifications
7935 engine is not correctly inserted If problem persists, call a qualifie dservice engineer
7934 formatter interface board is not correctly inserted If problem persists, call a qualified service engineer
7931 high temperature on smps check if air slot are free; clean airfilters If problem persists, call aqualified service engineer
7929 high temperature on smps check if air slot are free; clean airfilters If problem persists, call aqualified service engineer
7928 extreme overheating of dmd’s or lamp If problem persists, call a qualified service engineer
7927 fan is not running or is running tooslow If problem persists, call a qualified service engineer
8000 If problem persists, call a qualified service engineer
8001 If problem persists, call a qualified service engineer
8002 If problem persists, call a qualified service engineer
9000 Initialization of the scaler failed If problem persists, call a qualified service engineer
9198 BW or refresh rate of input sourcetoo high If problem persists, call a qualified service engineer
9398 Reaching the maximum allowednumber of files Delete some unnecessary files
10498 Module with obsolete firmware Call a qualified service engineer