Barco error code 5647, error code 6200, error code 7980, Barco Low Frequency Maintenance Error, Barco fan failure; voltage on fan group too high, fan is running too slow or not at all. Barco lamp replacement, hot restrike,lamp with many strikes, maximum run time exceeded, Temperature sensor on Red DMD shorted, initialization of the scaler failed error and many more.
Our Barco projector repair services covers the models below and future releases. We also carry out maintenance service for all Barco models.
Freya 4K RGB Laser, SP2K-9 8000 Lumens 2K Laser Phosphor, SP2K-7 6000 Lumens 2K Laser Phosphor, SP2K-15 14000 Lumens 2K Laser Phosphor, SP2K-11 11000 Lumens 2K Laser Phosphor, SP4K-50 48000 lumens 4K RGB Laser, SP4K-40 40000 Lumens 4K RGB Laser, SP4K-35 35000 Lumens 4K RGB Laser, SP4K-27HC 27000 lumens 4K RGB Laser, FS70-4K4 4000 Lumens 4K Laser Phosphor, F70-4K4 4000 Lumens 4K Laser Posphor, SP4K-25, 23500 Lumens 4K RGB Laser, SP4K-20 20000 Lumens 4K RGB Laser, SP4K-15 17000 Lumens 4K RGB Laser, SP4K-12 12000 Lumens 4K RGB Laser, XDL-4K30 30000 Lumens 4K RGB Laser, XDL-4K60 60000 Lumens 4K RGB Laser, F80-4K7 7000 Lumens 4K Laser Phosphor, F80-4K9,9000 Lumens 4K Laser Phosphor, DP4K-36BLP 35000 Lumens 4K Laser Phosphor, DP4K-40LHC 38000 Lumens 4K RGB Laser, FS70-W6 5500 Lumens WUXGA Laser Phosphor, FS70-4K6 5000 Lumens 4K Laser Phosphor, FS40-WU MKII 3000 Lumens 4K LED FS40-WU 2300 Lumens 4K LED, FS40-4K MKII 2700 Lumens 4K LED, FS40-4K 2100 Lumens 4K LED, FL40-WU MKII 3000 Lumens 4K LED, FL40-WU 2300 Lumens 4K LED, FL40-4K MKII 2700 Lumens 4K LE, FL40-4K 2100 Lumens 4K LED, F70-W6 5500 Lumens WUXGA Laser Phosphor, F70-4K6 5000 Lumens 4K Laser Phosphor, F90-4K13 11800 Lumens 4K Laser Phosphor, DP2K-20CLP 20000 Lumens 2K Laser Phosphor, DP2K-6E 7200 Lumens 2KLamp, DP4K-60L 56000 Lumens 4K RGB Laser, DP2K-10S 9000 Lumens 2K Lamp, DP4K-P 2700 Lumens 4K Lamp, DP4K-32B 33000 Lumens 4K Lamp, DP2K-20C 18500 Lumens 2K Lamp Balder 7000 Lumens 4K UHD Laser Phosphor, Balder Cinemascope 5600 Lumens Cinemascope (5,120 x 2,160)Laser Phosphor, Barco-Projector-Management-Suite IoT platform to monitor, diagnose and control your projectors Bragi 4K UHD LED 3D, Bragi Cinemascope 2100 Lumens Cinemascope (5,120 x 2,160) LED, DP2K-10SLP 9000 Lumens 2K Laser Phosphor, DP2K-15C 14500 Lumens 2K Lamp DP2K-15CLP 15000 Lumens 2K Laser Phosphor, DP2K-17BLP 17000 Lumens 2K Laser Phosphor, DP2K-19B 19000 Lumens 2K Lamp DP2K-23B 24500 Lumens 2K Lamp DP2K-23BLP 24000 Lumens 2K Laser Phosphor, DP2K-32B 33000 Lumens 2K Lamp DP2K-36BLP 35000 Lumens 2K Laser Phosphor, DP2K-8S 6000 Lumens 2K Lamp DP2K-8SLP 7000 Lumens 2K Laser Phosphor, DP4K-13BLPHC 11500 Lumens 4K Laser Phosphor, DP4K-17BLP 17000 Lumens 4K Laser Phosphor, DP4K-18BLPHC 16000 Lumens 4K Laser Phosphor, DP4K-19B 19000 Lumens 4K Lamp DP4K-23B 24500 Lumens 4K Lamp DP4K-23BLP 24000 Lumens 4K Laser Phosphor, F50 1080 5000 Lumens HD Lamp, F50 WQXGA 5000 Lumens WQXGA Lamp, 50 WUXGA 5500 Lumens WUXGA Lamp F70-4K8 7500 Lumens 4K Laser Phosphor, F70-W8 8000 Lumens WUXGA Laser Phosphor, F80-4K12 12000 Lumens 4K Laser Phosphor, F80-Q12 12000 Lumens WQXGA Laser Phosphor, F80-Q7 7000 Lumens WQXGA Laser Phosphor, F80-Q9 9000 Lumens WQXGA Laser Phosphor, F90-W13 13000 Lumens WUXGA Laser Phosphor, G100-W16 16000 Lumens WUXGA Laser Phosphor, G100-W19 19000 Lumens WUXGA Laser Phosphor, G100-W22 22000 Lumens WUXGA Laser Phosphor, G60-W10 10000 Lumens WUXGA Laser Phosphor, G60-W7 7000 Lumens WUXGA Laser Phosphor, G60-W8 8000 Lumens WUXGA Laser Phosphor, Loki 12000 Lumens 4K UHD Laser Phosphor, Loki Cinemascope 7800 Lumens Cinemascope (5,120 x 2,160) Laser Phosphor, MCM-100s External warping, blending and color matching Medea 6500 Lumens 4K UHD Laser Phosphor, Njord 4K UHD 3D Warping Orion Cinemascope 2000 Lumens Cinemascope (2,560 x 1,080) Lamp Prometheus I 6500 Lumens 4K Lamp Prometheus III 11500 Lumens 4K DCI Compliant Thor 15000 Lumens 4K RGB Laser Thor+ 32000 Lumens 4K RGB Laser UDM-4K15 14500 Lumens 4K Laser Phosphor, UDM-4K22 21000 Lumens 4K Laser Phosphor, UDM-W15 14500 Lumens WUXGA Laser Phosphor, UDM-W19 18500 Lumens WUXGA Laser Phosphor, UDM-W22 21000 Lumens WUXGA Laser Phosphor, UDX-4K26 25000 Lumens 4K Laser Phosphor, UDX-4K32 31000 Lumens 4K Laser Phosphor, UDX-4K40 37500 Lumens 4K Laser Phosphor, UDX-U32 30000 Lumens UXGA Laser Phosphor, UDX-U40 39000 Lumens UXGA Laser Phosphor, UDX-U45LC 41000 Lumens UXGA Laser Phosphor, UDX-W26 26000 Lumens WUXGA Laser Phosphor, UDX-W32 32000 Lumens WUXGA Laser Phosphor, UDX-W40 40000 Lumens WUXGA Laser Phosphor, XDL-4K75 75000 Lumens 4K RGB Laser Zeus 8000 Lumens 2K Lamp
1000-1017 | Wrong lamp/ no communication with lamp | Check lamp type Check lamp type Call a qualified service engineer | ||||||
1697 | no communication with formatter ctrl | Call a qualified service engineer | ||||||
1696 | no communication with formatter | Call a qualified service engineer | ||||||
1695 | no communication with red formatter | Call a qualified service engineer | ||||||
1694 | no communication with green formatter | Call a qualified service engineer | ||||||
1693 | no communication with blue formatter | Call a qualified service engineer | ||||||
1692 | formatter ‘Power Good’ signal not OK | Call a qualified service engineer | ||||||
2000 | no communication with lamp powersupply | Call a qualified service engineer | ||||||
2001 | mains voltage too low | Call a qualified service engineer | ||||||
2002 | Hot restrike Lamp with many strikes maximum run time exceeded Lamp or LPS or SPG failed | Let cool down the lamp for at least 5 minutes Retry a few times Replace the lampwith a new one Replace LPS or SPG or cabling | ||||||
2003 | mains voltage too high | Call a qualified service engineer | ||||||
2004 | Lamp goes out | Call a qualified service engineer | ||||||
2005 | Lamp stop failed | Call a qualified service engineer | ||||||
2201 | PFC start failed | Replace LPS | ||||||
2501 | PFC start failed | Replace LPS | ||||||
2801 | PFC start failed | Replace LPS | ||||||
2202 | LFC start failed | Replace LPS | ||||||
2502 | LFC start failed | Replace LPS | ||||||
2802 | LPS (address 0x28) | Replace LPS | ||||||
2203 | LPS (address 0x20) | Replace LPS | ||||||
2503 | LPS (address 0x22) | Replace LPS | ||||||
2803 | LPS (address 0x28) | Replace LPS | ||||||
2206 | hot restrike,lamp with many strikes, maximum run time exceeded | Let cool down the lamp for at least 3 minutes. Replace the lamp or SPG with a new one If problem persists, call a qualified service engineer | ||||||
2506 | hot restrike,lamp with many strikes, maximum run time exceeded | Let cool down the lamp for at least 3 minutes. Replace the lamp or SPG with a new one If problem persists, call a qualified service engineer | ||||||
2806 | hot restrike,lamp with many strikes, maximum run time exceeded | Let cool down the lamp for at least 3 minutes. Replace the lamp or SPG with a new one If problem persists, call a qualified service engineer | ||||||
2207 | lamp voltage too high or too low | Replace lamp | ||||||
2507 | lamp voltage too high or too low | Replace lamp | ||||||
2807 | lamp voltage too high or too low | Replace lamp | ||||||
2208 | lamp voltage too high or too low | Replace lamp | ||||||
2508 | lamp voltage too high or too low | Replace lamp | ||||||
2808 | lamp voltage too high or too low | Replace lamp | ||||||
4000 | Incompatible hardware used | Change to correct hardware | ||||||
4199 | no communication with FIB | Call a qualified service engineer | ||||||
5098 | Internal Backup device has reached its maximum capacity | Call a qualified service engineer | ||||||
5097 | Internal Backup device has reached its maximum capacity | Call a qualified service engineer | ||||||
5096 | Storing the custom settings into internal backup device has failed | If problem persists, call a qualified service engineer | ||||||
5095 | Restoring the custom settings from internal backup device has failed | If problem persists, call a qualified service engineer | ||||||
7698 | High temperature on light pipe entry | If problem persists, call a qualified service engineer | ||||||
7697 | Temperature sensor on light pipe not connected | Call a qualified service engineer | ||||||
7696 | Temperature sensor on light pipe shorted | Call a qualified service engineer | ||||||
7695 | Low temperature on red DMD | Switching on the lamp will heat up the DMD | ||||||
7694 | High temperature on red DMD | Check if air slots are free.Clean air filters.If problem persists, call a qualified service engineer | ||||||
7693 | Temperature sensor on Red DMD not connected | Call a qualified service engineer | ||||||
7692 | Temperature sensor on Red DMD shorted | Call a qualified service engineer | ||||||
7691 | Low temperature on green DMD | Switching on the lamp will heat upthe DMD | ||||||
7690 | High temperature on green DMD not connected | Check if air slots are free.Clean air filters.If problem persists, call a qualified service engineer | ||||||
7689 | Temperature sensor on green DMD | Call a qualified service engineer | ||||||
7688 | Temperature sensor on green DMD shorted | Call a qualified service engineer | ||||||
7687 | Low temperature on blue DMD | Switching on the lamp will heat upthe DMD | ||||||
7686 | High temperature on blue DMD | Check if air slots are free.Clean air filters.If problem persists, call a qualified service engineer | ||||||
7685 | Temperature sensor on blue DMD not connected | Call a qualified service engineer | ||||||
7684 | Temperature sensor on blue DMD shorted | Call a qualified service engineer | ||||||
7676 | High temperature on front DMD cooling block | Check if air slots are free.Clean air filters.If problem persists, call a qualified service engineer | ||||||
7675 | Temperature sensor on front cooling block not connected | Call a qualified service engineer | ||||||
7674 | Temperature sensor on front cooling block shorted | Call a qualified service engineer | ||||||
7672 | High temperature on red DMD cooling block | Check if air slots are free.Clean air filters.If problem persists, call a qualified service engineer | ||||||
7671 | Temperature sensor on red DMD cooling block not connected | Call a qualified service engineer | ||||||
7670 | Temperature sensor on red DMD cooling block shorted | Call a qualified service engineer | ||||||
7668 | High temperature on green DMD cooling block | Check if air slots are free.Clean air filters.If problem persists, call a qualified service engineer | ||||||
7667 | Temperature sensor on green DMD cooling block not connected | Call a qualified service engineer | ||||||
7666 | Temperature sensor on green DMD cooling block shorted | Call a qualified service engineer | ||||||
7664 | High temperature on blue DMD cooling block | Check if air slots are free.Clean air filters.If problem persists, call a qualified service engineer | ||||||
7663 | Temperature sensor on blue DMD cooling block not connected | Call a qualified service engineer | ||||||
7662 | Temperature sensor on blue DMD cooling block shorted | Call a qualified service engineer | ||||||
7660 | High temperature on engine | Check if air slots are free.Clean air filters.If problem persists, call a qualified service engineer | ||||||
7659 | Temperature sensor on engine notconnected | Call a qualified service engineer | ||||||
7658 | Temperature sensor on engineshorted | Call a qualified service engineer | ||||||
7999 | fan is running too slow or not at all | If problem persists, call a qualified service engineer | ||||||
7997 | fan is running too slow or not at all | If problem persists, call a qualified service engineer | ||||||
7995 | fan is running too slow or not at all | If problem persists, call a qualified service engineer | ||||||
7993 | fan is running too slow or not at all | If problem persists, call a qualified service engineer | ||||||
7991 | fan is running too slow or not at all | If problem persists, call a qualified service engineer | ||||||
7989 | fan is running too slow or not at all | If problem persists, call a qualified service engineer | ||||||
7987 | fan is running too slow or not at all | If problem persists, call a qualified service engineer | ||||||
7985 | low temperature on dmd | turning on the lamp will heat up the dmd | ||||||
7984 | high temperature on dmd | check if air slot are free; clean airfilters If problem persists, call a qualified service engineer | ||||||
7983 | low temperature on dmd | turning on the lamp will heat up the dmd | ||||||
7982 | high temperature on dmd | check if air slot are free; clean airfilters If problem persists, call a qualified service engineer | ||||||
7981 | low temperature on dmd | turning on the lamp will heat up thedmd | ||||||
7980 | high temperature on dmd | check if air slot are free; clean airfiltersIf problem persists, call a qualified service engineer | ||||||
7978 | high temperature lamp | check if air slot are free; clean airfilters If problem persists, call a qualified service engineer | ||||||
7976 | high temperature on smps | check if air slot are free; clean airfilters If problem persists, call a qualified service engineer | ||||||
7974 | ambient temperature abovespecification | check ambient conditionscheck if air slot are free; clean airfilters | ||||||
7973 | ambient temperature abovespecification | Hardware problem in Fan controlboard, call a qualified serviceengineer | ||||||
7972 | voltage on fan group 1 too high | Hardware problem in Fan controlboard, call a qualified serviceengineer | ||||||
7971 | voltage on fan group 2 too low (=anode fan) | Hardware problem in Fan controlboard, call a qualified serviceengineer | ||||||
7970 | voltage on fan group 2 too high | Hardware problem in Fan controlboard, call a qualified serviceengineer | ||||||
7969 | voltage on fan group 3 too low (=engine fan) | Hardware problem in Fan controlboard, call a qualified serviceengineer | ||||||
7968 | voltage on fan group 3 too high | Hardware problem in Fan controlboard, call a qualified serviceengineer | ||||||
7967 | voltage on fan group 4 too low (=cold mirror + head ex. fan) | Hardware problem in Fan controlboard, call a qualified serviceengineer | ||||||
7966 | voltage on fan group 4 too high (=cold mirror + head ex. fan) | Hardware problem in Fan controlboard, call a qualified serviceengineer | ||||||
7965 | voltage on fan group 5 too low (=mains input fan) | Hardware problem in Fan controlboard, call a qualified serviceengineer | ||||||
7964 | voltage on fan group 5 too highmains input fan) | Hardware problem in Fan controlboard, call a qualified serviceengineer | ||||||
7963 | voltage on fan group 6 too low (=smps fan) | Hardware problem in Fan controlboard, call a qualified serviceengineer | ||||||
7962 | voltage on fan group 6 too low (=smps fan) | Hardware problem in Fan controlboard, call a qualified serviceengineer | ||||||
7959 | voltage on pump too low | If problem persists, call a qualified service engineer | ||||||
7958 | voltage on pump too high | If problem persists, call a qualified service engineer | ||||||
7957 | supply voltage for fans too low | If problem persists, call a qualified service engineer | ||||||
7956 | supply voltage for fans too high | If problem persists, call a qualified service engineer | ||||||
7955 | supply voltage for DMD cooling toolow | If problem persists, call a qualified service engineer | ||||||
7954 | supply voltage for DMD cooling toohigh | If problem persists, call a qualifiedservice engineer | ||||||
7953 | supply voltage for motors too low | If problem persists, call a qualifiedservice engineer | ||||||
7952 | supply voltage for motors too high | If problem persists, call a qualifiedservice engineer | ||||||
7945 | supply voltage for electronics toolow | If problem persists, call a qualifiedservice engineer | ||||||
7944 | supply voltage for electronics toohigh | If problem persists, call a qualifiedservice engineer | ||||||
7943 | supply voltage for engineelectronics too low | If problem persists, call a qualifiedservice engineer | ||||||
7942 | supply voltage for engineelectronics too high | If problem persists, call a qualifiedservice engineer | ||||||
7941 | supply voltage for drawerelectronics too low | If problem persists, call a qualifiedservice engineer | ||||||
7940 | supply voltage for drawerelectronics too high | If problem persists, call a qualifiedservice engineer | ||||||
7939 | projection lens to close to prism | move lens away from prism (upand/or right) | ||||||
7938 | lamp module not correctly inserted | reinsert lamp module and screw firmly | ||||||
7937 | bad or no water flow in cooling circuit | If problem persists, call a qualified service engineer | ||||||
7936 | tilt angle is out of specifications | Correct projection installation.Change the tilting so that thetilt angle becomes within thespecifications | ||||||
7935 | engine is not correctly inserted | If problem persists, call a qualifie dservice engineer | ||||||
7934 | formatter interface board is not correctly inserted | If problem persists, call a qualified service engineer | ||||||
7931 | high temperature on smps | check if air slot are free; clean airfilters If problem persists, call aqualified service engineer | ||||||
7929 | high temperature on smps | check if air slot are free; clean airfilters If problem persists, call aqualified service engineer | ||||||
7928 | extreme overheating of dmd’s or lamp | If problem persists, call a qualified service engineer | ||||||
7927 | fan is not running or is running tooslow | If problem persists, call a qualified service engineer | ||||||
8000 | If problem persists, call a qualified service engineer | |||||||
8001 | If problem persists, call a qualified service engineer | |||||||
8002 | If problem persists, call a qualified service engineer | |||||||
9000 | Initialization of the scaler failed | If problem persists, call a qualified service engineer | ||||||
9198 | BW or refresh rate of input sourcetoo high | If problem persists, call a qualified service engineer | ||||||
9398 | Reaching the maximum allowednumber of files | Delete some unnecessary files | ||||||
10498 | Module with obsolete firmware | Call a qualified service engineer |